TSMaster Signal Comparison Module Operating Instructions

Sharing | TSMaster Signal Comparison Module Operation Guide is here!

overviewPreface

TSMaster Signal Comparison Module is a module specially developed for testing CAN, LIN, FlexRay and system variables. The module can accurately determine whether the signal value is within the set range in real time, and can save the signal acquisition data of the test process to a .CSV file, so that we can easily view the record information, import the file into various PC forms and databases to analyze the test records. Today, we will focus on sharing with you how to use the signal comparison module in TSMaster.

KEYWORDS IN THIS ARTICLE: Signal Comparison, CSV, Testing

Catalog/catalog

●  Adding and Editing Signal Comparison Modules

●  How to record and export test signals as CSV files

I. Adding and editing the signal comparison module

1. Add signal comparison module

Click [Signal Comparison Module] in the project menu bar [Test] and select [Add Signal Comparison Module].

Adding a Signal Comparison Module

2、Add signal

Right click in the Signal Comparison Module to bring up the tab and select Signal Type or select the type of signal we want to add in the upper left corner of the Signal Comparison Module.

Add Signal

Add the signal to be tested, take CAN signal as an example, press shift to complete the multi-selection of the signal, click OK after completing the signal selection, the signal is successfully added to the signal comparison module.

CAN signal

3. Unlocking the editor

Click Unlock Editor to edit the signal judgment conditions.

Unlock Edit

4、Edit signal judgment conditions

Double-click Calculation Method, Judgment Type, Maximum Minimum to edit the judgment conditions.

condition of judgment

Judgment Type Interpretation 

The type of judgment is = = =: Minimum value is valid, based on the minimum value judgment. 

The judgment type is > = :Maximum value is valid, based on the maximum value judgment. 

The judgment type is < = :Minimum Valid, based on the minimum value judgment. 

Judgment type is [ ] :Minimum value maximum value is valid, based on the maximum value minimum value range judgment, such as the above figure [0,150], the signal value in the 0 ≤ X ≤ 150 judgment is OK. 

Judgment type is Not[ ] :Minimum value maximum value are valid, based on the maximum value minimum value range judgment as above [0,150], the signal value in 0>X >150 judgment is OK. 

Interpretation of the calculation method 

Phy=(Raw*1+0)/1 where Raw value is the physical value of the current signal and Phy is the physical value obtained by the calculation method in the current module. If you need to calculate the current signal value and then judge it then edit it, otherwise the default calculation method is Phy=(Raw*1+0)/1 that is, Phy=Raw.

II. How to record and export test signals as CSV files

1. Add the signal to the signal record list

Enable signals that need to be recorded to the log file.

Signal Record List

2. Start recording test signals

Click Start Record after starting the signal comparison module.

TSMaster Signal Comparison Module Operating Instructions Starting a Recorded Test

Logging Configuration: 

Auto Start Record :Whether to start record automatically. Record Interval (ms) : Record the sampling interval.

TSMaster Signal Comparison Module Operating Instructions

3. Viewing log files after stopping logging

Click Start Record after starting the signal comparison module.

TSMaster Signal Comparison Module Operating Instructions Stop Recording

发表回复

en_USEnglish
×
×

产品入口: 产品添加到购物车

Download location

Please click the download button below to start experiencing the powerful TSMaster features. Thank you for your support!

Beta version updated weekly, full version updated monthly
Installation environment
  • 1
    Windows 7 SP1 or higher, supports Win10, and WIn11.

    Operating System

  • 2
    8GB

    random access memory (RAM)

  • 3
    At least 550MB of free space

    disk space

  • 4
    Dual-core (2-core) or higher

    CPU

Please ensure that your computer meets at least these requirements in order to install and run the TSMaster software successfully. If your computer does not meet these requirements, it may cause performance problems or not run the software properly. You may want to consider upgrading your hardware if you need smoother running features.
XML 地图