太阳集团6138(CHINA)澳门企业-环球百科 /en/product/gcm48/ /en/product/gcm48/#respond Fri, 19 Sep 2025 07:48:17 +0000 /?post_type=product&p=21020 The GCM48-2104 is a highly reliable Raptor controller that supports 6 CAN and 3 LIN (2 masters and 1 slave), and is equipped with a rich set of input and output interfaces. It combines MATLAB/Simulink and Raptor-Dev tools for rapid application development and testing, and is suitable for various vehicle electronic control scenarios.

The post GCM48 – 通用控制模块 first appeared on 上海太阳集团6138科技有限公司.

]]>
  • Supports 6 CAN 2.0 buses and 3 LIN buses (configurable master-slave mode), wake-up compatible
  • Provides 12 analog inputs, 4 frequency inputs, and 1 wake-up input.
  • Equipped with 7 low-side drive outputs, independent fuel gauge drive output and one H-bridge drive output.
  • The core processor is the NXP MPC5605B, clocked at 64MHz, with 512KB of application flash and 64KB of RAM.
  • Supply voltage range 8-16V, with multiple overcurrent/reverse/short-circuit protection
  • Supports automated code generation and simulation test development on MATLAB/Simulink + Raptor-Dev platforms.
  • Industrial grade environmental design, -40°C ~ 105°C operating temperature, protection class IP6k7
  •  

    Correspondence:

    The GCM48-2104 module has a total of 6 CAN 2.0 buses. The module supports Wake-on-CAN function.
    The module also has 3 LIN buses. LIN2 and LIN3 are fixed in LIN host mode, while LIN1 can be configured as LIN master or LIN slave in Raptor. The module also supports the LIN wake-up function.

    Power supply:

    The logic battery input needs to be permanently connected to the battery voltage to supply power when the microprocessor is in the wake-up state. This logic battery input should be individually fused to avoid excessive current flow in the system that could compromise the safety of the logic power supply routing.

    Maximum rating:

    Min Nom Max. Unit
    Input voltage: Normal operation 8 12 16 V
    Batt+ pin total current capability 24 A
    Load Sudden Drop Protection 30 V
    Jumper start (max. 5 minutes) 17 V
    Reverse battery protection (up to 5 minutes) -13.8 V

     

    Operating ratings:

    Parameters norm
    Power Off (Batt On, Key Switch Off) Current Consumption <10uA Nominal
    Key Switch On, No-Load Current Consumption ~90mA
    Key Switch Input Current Consumption 5mA

    The post GCM48 – 通用控制模块 first appeared on 上海太阳集团6138科技有限公司.

    ]]>