太阳集团6138(CHINA)澳门企业-环球百科 /en/get-tosun-lin-function-operation-process-in-3-minutes/ Fri, 09 Dec 2022 08:44:43 +0000 /?p=2091 In this article, LIN stands for Local Interconnect Network and is based on UART/SCI ( [...]

The post 3 Minute Guide to Operating TOSUN LIN hardware first appeared on Shanghai TOSUN Technology Ltd..

]]>

Introduction to this article

LIN stands for Local Interconnect Network and is a low-cost serial communication protocol based on UART/SCI (Universal Asynchronous Receiver-Transmitter / Serial Communication Interface). It can be used in a variety of fields such as automobiles, home appliances, and office equipment.

This article focuses on a detailed tutorial on the operation process of the same star LIN master and slave node emulation functions and other functions.

I. Operation of the same star LIN master node simulation function

1、Hardware connection preparation

Using the same star LIN hardware simulation master node mode, external power supply is required, in order to keep the LIN bus level signal consistent with the measured parts, the connection schematic is as follows.

Operation procedure of the same star LIN function

2、TSMaster software operation process

The following operation flow is exemplified by the TSMaster simulation LIN master node, and the measured part slave node is LED light.

2.1 Importing LDF file database

After adding the LDF file of LEDs through the database, you can see that the [nodes] in the LDF file are [master] and [RGB_Slave] respectively, and contain the master node scheduling table information, message and signal definitions.

Operation procedure of the same star LIN function

2.2 Create LIN send window and perform LIN master node configuration

Check [master node mode], then select Run_normal for the run scheduling table and select emulation [master master node], you can see that two messages of the scheduling table are checked. At this time, you can [Deploy] run the scheduling table.

Operation procedure of the same star LIN function

▲ [Note]: You need to pay attention to the sending direction of the master and slave node messages in the scheduling table.

Emulate the message direction of master master node: [send]

The direction of the message from the node response is: [Received]

That is, message 0x02 is a control message sent from the master node to the RGB slave node, so the direction is transmitting, while message 0x10 is for the RGB feedback from the slave node to the master node, so the direction is receiving.

2.3 LIN message information monitoring

Under normal circumstances, after the scheduling table is running, the data contents of two messages can be viewed in the LIN message information window, indicating that the slave node is communicating with the master node normally and feeding back data.

Operation procedure of the same star LIN function

 

▲Non-normal situation: If the response data of the message from the slave node is empty, it can be judged that the slave node is not responding, at this time, you can check whether the LIN bus connection is correct or whether the power supply of the LIN slave node is normal, etc., as shown in the following figure

Operation procedure of the same star LIN function

2.4 Modify the content of LIN master node control message

In the [LIN transmit window], select the master node message such as 0x02, you can directly modify the original value or physical value of the LIN signal to assign the message signal.

Operation procedure of the same star LIN function

By modifying the signal values of the three different colors of RGB, the same light colors can be combined. The following figure shows the lighting of RGB lights for reference.

Operation procedure of the same star LIN function

3. [Example 1] LIN diagnostic function - automatic address assignment

Usually before RGB lighting function test, it is necessary to auto-assign address to RGB lights before light color, brightness test, version number reading, etc. can be performed.

[Background]: According to the protocol of LIN automatic address assignment, multiple 3C diagnostic messages need to be sent for address assignment at a single time, and TSMaster is available through [Single Frame] mode.

The message for the automatic address assignment of RGB lights is as follows.

1. Single send: 7F 06 B5 FF 7F 01 02 FF

2. Single send: 7F 06 B5 FF 7F 02 02 01

3. Single send: 7F 06 B5 FF 7F 03 02 FF

4. Single send: 7F 06 B5 FF 7F 04 02 FF

[Hands-on]: Run the diagnostic command in [Single Frame] of TSMaster software, create the corresponding messages and send message lines 1, 2, 3 and 4 from top to bottom respectively to complete the automatic RGB address assignment.

Operation procedure of the same star LIN function

4. 【Example 2】 The use of insert_lin_message function for inserting message frames

There is a common usage scenario to insert a frame of other LIN message, such as 0x3C message, when the emulation master node is running the scheduling table without stopping the running scheduling table, this function can be implemented by the inject_lin_message function.

Create a new C Script Editor and select [Keystroke Events], for example, create keystroke "A" to execute the insertion message.

Operation procedure of the same star LIN function

The sample code is as follows.

TLIN f0 = {0,0×0,0x1,8,0x3C,0x0,0,0,{0x11, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00};

com.inject_lin_message(&f0);

app.wait(10, "");


Then compile and run the C script, and with the deployment schedule running, press the "A" key, and you can observe the 3C messages being sent in the LIN message message.

Operation procedure of the same star LIN function

[TSMaster Software Tips - Quickly Generate C Code for LIN Messages]: You can create a new LIN message in the scheduling table and right-click to copy it as a C script to quickly copy the C code of the message to the script.

Operation procedure of the same star LIN function
Operation procedure of the same star LIN function

Second, the same star LIN slave node / listener node function operation

1. Hardware connection preparation

Emulation of slave nodes can be done without powering the same star LIN card.

Operation procedure of the same star LIN function

2. emulate the slave node to send response messages

When the same star LIN card is emulated as a slave node, the ECU master node needs to send the header Header of the scheduling table for the slave node response message to be sent normally.

In this paper, the LIN channel 1 of TSMaster emulates the master node running the scheduling table, and LIN channel 2 emulates the slave node responding to message 0x10 (Tech_Info_RGB_Slave).

First, LIN channel 1 emulates the master node running the scheduling table, where the header direction of the response message from the slave node is [received].

Operation procedure of the same star LIN function

After the deployment is running, you can see that the LIN slave node message header has been sent and the data is empty.

Operation procedure of the same star LIN function

Then, the LIN channel 2 emulation slave node sends a response message 0x10 (Tech_Info_RGB_Slave) in the direction of [send], modifying the data content.

Operation procedure of the same star LIN function

2 Click [Deploy], you can observe from the LIN message information that the slave node message 0x10 successfully sends a response message, and the master node also receives it successfully.

Operation procedure of the same star LIN function

The post 3 Minute Guide to Operating TOSUN LIN hardware first appeared on Shanghai TOSUN Technology Ltd..

]]>